T1000
|
Features:
- 3U rack mounting
- Overheat,overload and short circuit protection
- Innovative heat sink structure
- Accurate signal amplifier,high S/N ratio
- Operation mode switchable(Mone,Stereo,Bridge mono)
- Amplification times switch(20 times/40 times/0.775V)
- Ground switchable(Lift/Gnd)
- Bridge LED indication
- Power LED indication
- Protection LED(LED will be active when overvoltage,ovrcurrent or overheat/failure)
- Adopting soft clip process when overload
- Speed of cooling fan is autmatic adujusted by power to get the best heat radiation
|
|
|
|
Front Panel:

Rear Panel:

Specifications:
Output power:
|
|
| Stereo(W/Ch) 8ohm/4ohm |
300W/450W |
Bridged-Mono 8ohm/4ohm
|
1000W/1200W |
| Frequency Response: |
20Hz-50KHz(+/-0.1) |
| Phase Response |
+/-5 degree from 20Hz-50KHz |
| Signal to noise ratio |
105dB(A-weighted)at full output and 28 dB GAIN |
| Total harmonic distortion(THD) |
<0.03% from 20Hz-50KHz to 1KHz increasing linearly to 0.1% at 50KHz |
| Intermodulation distortion(IMD) |
<0.03% from 10mW to 300W,400W,550W,1000W at 28dB gain |
| Slew Rate |
>26V per microsecond |
| Damping factor |
>200 from 20Hz-400Hz |
| Load impedance |
ratied for 16,8,4,2ohm use. Safe with all types of loads,even reactive ones |
| Required AC mains |
50Hz,220V-240V |
| AC line connector |
standard three-wire grounded connector |
| Net dimensions |
485×445×130mm |
| Net weight |
20Kg |
|
|
※ All features and specifications are subject to change without notice